Installation
Import Installer and Solution Management
Follow the instructions of the general Installation page to set up the base configuration needed for solutions.
Install The Solution
You can follow the instructions of Install A Solution Or Module to install the solution.
The solution name to choose when running the Install Solution method will be Quality.
Validate Appsettings-file
File Appsettings.json contains all configuration variables that are used during the installation of the solution.
Variables that require validation are shown in following table.
| Variable | Description | Value |
|---|---|---|
| FrameworkExportZipName | The name of the ZIP file which is imported into the Ometa Framework. | QualityFramework.zip |
| Scripts | Contains an overview of SQL or PowerShell script names that are executed during installation. | |
| Connectionstring | The connectionstring to the SQL instance in which the solution database exists, having the solution database as default . | |
| CoreUrl | The value of the Core Service Url, used in the custom files that make up the solution. | The Core Service Url of the Ometa installation. |
| Methods | The method(s) to be executed during installation of Quality Control. | See below |
As this is a JSON-file, special characters must be escaped. A backslash ('\') is escaped as '\'.
Realtime Keys
As Quality Control is normally integrated in an operating dashboard, it is possible to push newly generated Quality Controls automatically to the operators, using Realtime Keys. To enable realtime data, a trigger method needs to be executed after adding new quality controls to the database. An input field named after (one of) the key field(s) of the view that provides the quality control to the operators, must be sent with this method, for example 'Production Order'. Its value should match the order that needs a quality check.
The value itself does not need to be configured, as it will be fetched from the given Ometa case by searching for a case property with the same name.
The configuration is done in the appsettings-file, under the Methods\InputFields-node. For method Create Solution Config By Solution Title, configure the four empty values under the input fields with name 'Config Value' and provide values for the object, method, profile and field to pass with the method.
Dashboard Generation
A dashboard will also be provided during installation of the solution. Below values need to be configured in the appsettings-file, under the Methods\InputFields-node.
| Method | Field | Value |
|---|---|---|
| Add Redirect URL | Redirect Url | The Core Service Url of the Ometa-installation, without the ending '/'. |
| Change URL Mapping | Internal Url Prefix | The Core Service Url of the Ometa-installation, without the ending '/'. |
| Create Dashboard | Dashboard Relative Url | The relative Url to the folder under the Core Service, where the dashboard files are copied, starting with '/'. |
| Create Dashboard | Plant | The plant that is linked to the dashboard This value can be left empty if no multi-plant solution is used. |
Post-Installation Actions
Add Security
The quality solution is set up as a dashboard outside of SharePoint, which allows all company users to access it. To provide security to a certain group of users, an Ometa Case needs to be created.
During installation, a Quality Dashboard has already been created. If you wish to use multiple dashboards, each for a separate plant, you can create these via method 'Create Dashboard' within object 'Quality - Dashboard'. Following fields need to be filled in:
| Field | Description |
|---|---|
| Dashboard Relative Url | The relative Url to the folder under the Core Service, where the dashboard files are copied, starting with '/'. |
| Plant | The plant that is linked to the dashboard. |
Via the Case Management Dashboard, users can now be added to one of the following rules, to be able to use the solution:
| Role | Description |
|---|---|
| Administrator | Grants the user full access to the entire solution. |
By default, Ometa Framework Administrators bypass security, and will therefore be able to use the entire solution. This can be changed by disabling the Skip Security Checks for Admins-setting in the Ometa config table.